Exclusive IPD distributor for the Czech and Slovak RepublicsOriginal components · CAD/CAM libraries · technical support+420 604 483 343obchod@exklusiv-dent.cz
CATALOGUE 2026STANDARDTPAIPDMILLED

The exact value instead of an estimate

Tightening torques IPD fixation screws

Find the torque by reference, compatibility, platform or screwdriver.

The table contains technical values for standard Ti, TiN and BLC screws, angulated TPA screws and special IPDmilled screws from the IPD 2026 catalogue.

Torque ratchet and system screwdrivers for IPD fixation screws
159 technical rowsStandard, TPA a IPDmilled
10, 15, 20, 24, 25, 30, 32, 35 NcmRange of values in the tables

The table is a technical reference, not a substitute for the current Instructions for Use

If there is any discrepancy, the value on the current label or blister of the specific product and the valid IPD Instructions for Use take precedence. Pay particular attention to TPA, Multi-Unit, SRA and IPDmilled references.

Search technical specifications

Find the exact row by reference

The search is case-insensitive and works with slashes, system names, platform and screwdriver type.

Shown of 159 rows

Product typeReferenceTiN / BLC variantCompatibilityPlatformDriverTorque
No row was found for the selected combination.

Data source: IPD Product Catalogue 2026, technical specifications for screws, TPA screws and special IPDmilled screws, pages 208–212. A row marked “verify” indicates a value that was not printed unambiguously in the source technical table.

How to use the table

Reference first, torque second

1

Read the REF

Use the designation on the packaging or confirmed product documentation.

2

Compare the system

Check the compatibility and platform stated in the same row.

3

Verify the screwdriver

The correct geometry and size protect the screw head from damage.

4

Confirm the Ncm value

Before tightening, check the label, blister and current Instructions for Use.

Important differences

The same system may use several torque values

Values in the technical tables range from 10 to 35 Ncm. They differ between implant and abutment level, standard and TPA channels, and individual platforms.

10Ncm
15Ncm
20Ncm
24Ncm
25Ncm
30Ncm
32Ncm
35Ncm

Common questions

Tightening torque without guesswork

Individual series and platforms use different threads, diameters, seats and mechanical protocols.
Yes. Selecting the TPA type displays a separate technical table. The value must not be taken from the standard screw for the same brand.
The value was not printed unambiguously in the source technical table. Check the packaging or contact technical support before use.

Technical support for the Czech and Slovak Republics

Cannot find the reference or do the values differ?

Send a photograph of the label or blister and the implant designation. We will verify the current torque and correct screwdriver.

Request verification

Important information for use

The table is a reference tool. The label of the specific screw takes precedence.

The torque finder helps with identification, but final verification must be based on the current label, blister and Instructions for Use for the specific reference.

  • Do not automatically transfer the torque value between standard, TPA, TiN or BLC screws.
  • Products are supplied non-sterile; sterilise according to the current Instructions for Use.
  • If in doubt, send technical support a photograph of the label or blister.
e-dent logo